  hp ordering information relay for control panel of 10a (2c/3c/4c) hp relays features 1. high-capacity and long life mechanical life is more than 10 million operations and, with electrical life of more than 200,000 operations (resistive load 10 a; inductive load 7.5 a), the relay has excellent inductive load durability. 2. easy mounting and wiring the terminal arrangement is apparent at a glance and wiring is easy. moreover, quick tab terminal is also possible. 3. operation indicator option optional operation indicators are av ailable for easy visual con?mation that relays are operating. they simplify maintenance. 4. wide range of sockets and terminal sockets to enable use with din rails, din terminal sockets are also available. typical applications hp relays enjoy wide use in various applications, particularly in automation controls and remote controls. applications include: 1. industrial machinery f or controlling positioning, pressure, and temperature in molding equipment, boilers, pumps, charging pressure equipment, measuring and evaluation equipment, textile machines, etc. 2. machine tools control of positioning and directional change in turning machines, lathes, borers, etc. 3. food processing packing machines automatic control of packing equipment for milk and seafood, bottling, canning, and packaging 4. of?e equipment control of copiers, time recorders, etc. 5. coin operate machines control of food, cigarette, and other vending machines 6. measuring devices and equipment for repeating installation of control signals and in power ampli?rs 7. generators, transformers and power receiving equipment. functional parts in protective equipment, functional assistance in automatic adjustment equipment, telemeters and other remote monitoring equipment 8. control of conveyance equipment control panels for elevators, escalators, and other conveyance equipment, control of all kinds industrial transport equipment such as conveyors. 9. amusement equipment control of equipment in amusement parks, etc., control of bowling alley equipment, control of fountains in public parks contact arrangement 2: 2 form c 3: 3 form c 4: 4 form c hp operation indication nil: l: without indication with indication contact material f: nil: 4 form c, silver alloy (cadmium-free) 2 form c, 3 form c (silver) with led indicator type nominal coil voltage: with neon lamp type nominal coil voltage: 24 v ac 12, 24, 48 v dc 100, 115, 200, 220, 240 v ac 100, 110 v dc terminal arrangement nil: tm: m: plug-in terminal tm type (2 form c only) direct mounting (3 form c only) nominal coil voltage ac dc 24, 48, 100, 115, 200, 220, 240 v 12, 24, 48, 100, 110 v asctb81e 201201-t panasonic corporation automation controls business unit industrial.panasonic.com/ac/e rohs compliant
hp types 1. plug-in type standard packing (2 form c): carton: 20 pcs.; case: 100 pcs. standard packing (3 form c, 4 form c): carton: 10 pcs.; case: 50 pcs. 2. plug-in type (with operation indication) standard packing (2 form c): carton: 20 pcs.; case: 100 pcs. standard packing (3 form c, 4 form c): carton: 10 pcs.; case: 50 pcs. 3. tm type and direct mount type standard packing: carton: 10 pcs.; case: 50 pcs. 4. direct mount type (with led indication) standard packing: carton: 10 pcs.; case: 50 pcs. notes: 1. standard packaging is handled in units of inner cartons. please specify if you require inner cartons to be boxed. 2. sockets, terminal sockets and installation brackets are not included. please order these separately. 3. for products compliant with international standards, please refer to the standards chart. * for sockets and terminal sockets, see page 117. nominal coil voltage 2 form c 3 form c 4 form c part no. part no. part no. 24v ac hp2-ac24v hp3-ac24v hp4-ac24v-f 48v ac hp2-ac48v hp3-ac48v hp4-ac48v-f 100v ac hp2-ac100v HP3-AC100V hp4-ac100v-f 115v ac hp2-ac115v hp3-ac115v hp4-ac115v-f 200v ac hp2-ac200v hp3-ac200v hp4-ac200v-f 220v ac hp2-ac220v hp3-ac220v hp4-ac220v-f 240v ac hp2-ac240v hp3-ac240v hp4-ac240v-f 12v dc hp2-dc12v hp3-dc12v hp4-dc12v-f 24v dc hp2-dc24v hp3-dc24v hp4-dc24v-f 48v dc hp2-dc48v hp3-dc48v hp4-dc48v-f 100v dc hp2-dc100v hp3-dc100v hp4-dc100v-f 110v dc hp2-dc110v hp3-dc110v hp4-dc110v-f nominal coil voltage 2 form c 3 form c 4 form c part no. part no. part no. with led indication 24v ac hp2-l-ac24v hp3-l-ac24v hp4-l-ac24v-f with neon lamp 100v ac hp2-l-ac100v hp3-l-ac100v hp4-l-ac100v-f 115v ac hp2-l-ac115v hp3-l-ac115v hp4-l-ac115v-f 200v ac hp2-l-ac200v hp3-l-ac200v hp4-l-ac200v-f 220v ac hp2-l-ac220v hp3-l-ac220v hp4-l-ac220v-f 240v ac hp2-l-ac240v hp3-l-ac240v hp4-l-ac240v-f with led indication 12v dc hp2-l-dc12v hp3-l-dc12v hp4-l-dc12v-f 24v dc hp2-l-dc24v hp3-l-dc24v hp4-l-dc24v-f 48v dc hp2-l-dc48v hp3-l-dc48v hp4-l-dc48v-f with neon lamp 100v dc hp2-l-dc100v hp3-l-dc100v hp4-l-dc100v-f 110v dc hp2-l-dc110v hp3-l-dc110v hp4-l-dc110v-f nominal coil voltage 2 form c (tm type) 3 form c (direct mount type) part no. part no. 24v ac hp2-tm-ac24v hp3-m-ac24v 48v ac hp2-tm-ac48v hp3-m-ac48v 100v ac hp2-tm-ac100v hp3-m-ac100v 115v ac hp2-tm-ac115v hp3-m-ac115v 200v ac hp2-tm-ac200v hp3-m-ac200v 220v ac hp2-tm-ac220v hp3-m-ac220v 240v ac hp2-tm-ac240v hp3-m-ac240v 12v dc hp2-tm-dc12v hp3-m-dc12v 24v dc hp2-tm-dc24v hp3-m-dc24v 48v dc hp2-tm-dc48v hp3-m-dc48v 100v dc hp2-tm-dc100v hp3-m-dc100v 110v dc hp2-tm-dc110v hp3-m-dc110v nominal coil voltage 3 form c part no. with neon lamp 100v ac hp3-ml-ac100v 115v ac hp3-ml-ac115v 200v ac hp3-ml-ac200v 220v ac hp3-ml-ac220v 240v ac hp3-ml-ac240v 100v dc hp3-ml-dc100v 110v dc hp3-ml-dc110v asctb81e 201201-t panasonic corporation automation controls business unit industrial.panasonic.com/ac/e
hp rating 1. coil data 1) ac coils 2) dc coils (20 c 68f) notes: 1. the nominal current area is 15% (60hz) [ac coils],. 10% (20 c) [dc coils] 2. the coil resistance for dc operation is the value measured when the coil temperature is 20 c 68f . compensate 0.4% for every 1 c change in temperature. 3. the relay operates in a range of 80% to 110% v of the nominal coil voltage, but ideally, in consideration of temporary voltage ?ctuations, it should be operated at the nominal coil voltage. in particular, for ac operation, if the impressed voltage drops to 80% v or more below the nominal coil voltage, humming will occur and a large current will ?w leading possibly to coil burnout. 4. for use with 200 v dc, connect a 6.7k ? (10w) resistor, in series, to the 100 v dc relay [3 form c type is .6.4k ? (5w); 4 form c type is .6.2k ? (10w)]. 5. as a general rule, only a pure dc voltage should be used for the coil drive. however, a dc power supply that contains ripples has characteristics that differ from pure dc. therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used. contact arrangement nominal coil voltage nominal operating current (ma) nominal operating power (va) inductance (h) pick-up voltage (at 20 c 68 f) drop-out voltage (at 20 c 68f) max. applied voltage (at 20 c 68f) 50hz 60hz 50hz 60hz 50hz 60hz 2 form c 24v ac 94ma 78ma 2.25va 1.9va 0.753 0.776 80%v or less of nominal voltage (initial) 30%v or more of nominal voltage (initial) 110%v of nominal voltage 48v ac 46.5ma 39ma 2.23va 1.9va 3.055 3.106 100v ac 25.3ma 21ma 2.36va 2.1va 12.60 12.03 115v ac 23.1ma 18ma 2.31va 2.1va 16.70 15.83 200v ac 12.4ma 11ma 2.48va 2.2va 48.03 45.81 220v ac 10.6ma 9.5ma 2.34va 2.1va 61.28 57.90 240v ac 10.0ma 9.0ma 2.40va 2.2va 69.00 66.26 3 form c 24v ac 148.7ma 130ma 3.56va 3.1va 0.0494 0.475 80%v or less of nominal voltage (initial) 30%v or more of nominal voltage (initial) 110%v of nominal voltage 48v ac 74.2ma 65ma 3.56va 3.1va 1.976 1.899 100v ac 36.4ma 32ma 3.64va 3.2va 8.500 8.038 115v ac 32.5ma 28.5ma 3.74va 3.3va 10.79 10.36 200v ac 18.2ma 16ma 3.65va 3.2va 33.53 32.10 220v ac 16.0ma 14.2ma 3.54va 3.1va 41.35 39.32 240v ac 15.8ma 13.9ma 3.79va 3.3va 45.94 44.05 4 form c 24v ac 229ma 200ma 5.49va 4.8va 0.320 0.309 80%v or less of nominal voltage (initial) 30%v or more of nominal voltage (initial) 110%v of nominal voltage 48v ac 108ma 95ma 5.18va 4.6va 1.348 1.292 100v ac 57.3ma 50ma 5.73va 5.0va 5.348 5.156 115v ac 47.6ma 42ma 5.47va 4.8va 7.264 6.953 200v ac 28.5ma 25ma 5.69va 5.0va 21.27 20.45 220v ac 23.8ma 21ma 5.24va 4.6va 27.75 26.57 240v ac 23.3ma 20.5ma 5.58va 4.9va 30.98 29.75 contact arrangement nominal coil voltage nominal current (ma) nominal operating power (w) coil resistance (?) pick-up voltage (at 20 c 68 f) drop-out voltage (at 20 c 68f) max. applied voltage (at 20 c 68f) 2 form c 12v dc 109ma 1.3w 110 ? 80%v or less of nominal voltage (initial) 15%v or more of nominal voltage (initial) 110%v of nominal voltage 24v dc 54.5ma 1.3w 440 ? 48v dc 26.7ma 1.3w 1,800 ? 100v dc 14.9ma 1.5w 6,700 ? 110v dc 15.0ma 1.7w 7,300 ? 3 form c 12v dc 120ma 1.4w 100 ? 80%v or less of nominal voltage (initial) 15%v or more of nominal voltage (initial) 110%v of nominal voltage 24v dc 60ma 1.4w 400 ? 48v dc 31ma 1.5w 1,560 ? 100v dc 15.6ma 1.6w 6,400 ? 110v dc 14.9ma 1.6w 7,450 ? 4 form c 12v dc 127ma 1.5w 95 ? 80%v or less of nominal voltage (initial) 15%v or more of nominal voltage (initial) 110%v of nominal voltage 24v dc 63ma 1.5w 380 ? 48v dc 32.0ma 1.5w 1,500 ? 100v dc 16.3ma 1.6w 5,950 ? 110v dc 15.7ma 1.7w 7,000 ? asctb81e 201201-t panasonic corporation automation controls business unit industrial.panasonic.com/ac/e
hp 2. speci?ations notes: *1. this value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. *2. for the ac coil types, the operate/release time will differ depending on the phase. *3. the upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. refer to usage, transport and storage conditions in notes. 3. electrical life 1) ac load note: when the electromagnet or exciting coil (solenoid, etc.) is the load, the value of motor or lamp load is applicable. 2) dc load notes: 1. for dc inductive loads, use an arc suppressing circuit. 2. cautions at dc load use when used under a dc load operating at high repetition rate with considerable arcing, corrosion of the contacts and/or the contact blades is likely to occur. characteristics item speci?ations contact arrangement 2 form c, 3 form c, 4 form c contact resistance (initial) max. 15 m ? (by voltage drop 6 v dc 1a) contact material 2 form c, 3 form c ag 4 form c ag alloy (cd free) rating nominal switching capacity 10a 250v ac (resistive load) min. switching capacity (reference value)* 1 100ma 5v dc electrical characteristics insulation resistance (initial) min. 100m ? (at 500v dc) measurement at same location as ?reakdown voltage section. breakdown voltage (initial) between open contacts 1,000 vrms for 1min (2 form c, 4 form c). 2,000 vrms for 1min (3 form c) (detection current: 10ma.) between contact sets 1,500 vrms for 1min (2 form c, 4 form c). 2,000 vrms for 1min (3 form c) (detection current: 10ma.) between contact and coil 1,500 vrms for 1min (2 form c, 4 form c). 2,000 vrms for 1min (3 form c) (detection current: 10ma.) temperature rise (coil) max. 65 c 149f (by temperature method, at 40 c, nominal current) operate time* 2 max. 25ms (2 form c), max.30ms (3 form c, 4 form c) (nominal coil voltage applied to the coil, excluding contact bounce time.) release time* 2 max. 25ms (2 form c), max.30ms (3 form c, 4 form c) (nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) mechanical characteristics shock resistance functional min. 98 m/s 2 (half-wave pulse of sine wave: 11 ms; detection time: 10 s.) destructive min. 980 m/s 2 (half-wave pulse of sine wave: 6 ms.) vibration resistance functional 10 to 55 hz at double amplitude of 1 mm (detection time: 10 s.) destructive 10 to 55 hz at double amplitude of 2 mm expected life mechanical min. 10 7 conditions conditions for operation, transport and storage* 3 ambient temperature: ?0 c to +40 c ?8 f to +104 f humidity: 5 to 85% r.h. (not freezing and condensing at low temperature) max. operating speed 20 times/min. (at max. rating) unit weight 2 form c: approx. 60g 2.12oz , 3 form c: approx. 100g 3.53oz , 4 form c: approx. 125g 4.41oz voltage 125v ac 250v ac expected life load resistive load (a) (cos ? =1) inductive load (a) (cos ? =0.4) resistive load (a) (cos ? =1) inductive load (a) (cos ?=0.4) current 10 7.5 min. 2 10 5 10 7.5 7.5 5 min. 5 10 5 5332 min. 10 6 1 0.7 0.6 0.4 min. 2 10 6 voltage 24v dc 125v dc expected life load resistive load (a) inductive load (a) resistive load (a) inductive load (a) current ? min. 2 10 5 7.5 5 0.5 0.4 min. 5 10 5 53 0.3 0.2 min. 10 6 1 0.6 0.1 0.06 min. 2 10 6 asctb81e 201201-t panasonic corporation automation controls business unit industrial.panasonic.com/ac/e
hp 4. life of led and neon lamp (with operation indication) reference data dimensions (mm inch ) continuous use rating (on time) 50% with neon lamp 25,000 hours (approx. 3 years) approx. 6 years with led indication 50,000 hours (approx. 5.5 years) 100,000 hours (approx. 11 years) (coil terminal no.) schematic led protection diode schematic with led indication led with neon lamp neon lamp (coil terminal no.) coil terminal no. and polarity (dc type) polarity 2 form c 3 form c 4 form c te r minal no. (+) 7 10 10 (? 2 2 1 1. life curve 2. max. switching capacity 10 0 100 200 300 400 500 600 700 800 900 1,000 load current, a operations, 10 4 125 v ac cos ? = 1 5 2 5 0 v a c c o s ? = 1 mechanical life more than 10,000,000 operations 100 500 1,00010 10 1 0.1 dc inductive load (l/r=7ms) ac inductive load (cos ? =0.4) dc resistive load ac resistive load contact voltage, v contact current, a the cad data of the products with a cad data ma r k can be d o wnloaded from: http://industrial.panasonic.com/ac/e 7 .276 51 2.008 .197.315 .197 58 5 44 1.732 0.5 .020 25 15 .984 .591 .031 8 7 63 54 1 5.26 5.26 5.26 .207 .207 10 .394 9.5 .374 7.5 .295 36 1.417 5.8 .228 5.3 .209 5.26 .207 .207 2 .031 0.8 0.8 0.8 0.8 .031 .031 compatible with tab terminal #205 series receptacle. plug-in type (2 form c) external dimensions schematic (bottom view) 8 7 6 5 1 2 3 4 cad data dimension: less than 2mm .079inch : min. 2mm .079inch less than 9mm .354inch : min. 9mm .354inch less than 20mm .787inch : min. 20mm .787inch : t oler ance 0.2 .008 0.5 .020 1 .039 1.5 .059 asctb81e 201201-t panasonic corporation automation controls business unit industrial.panasonic.com/ac/e
hp 0.5 .020 44 1.732 3 .118 7 .276 .197 5 38 1.496 36 1.417 36 1.417 38 1.496 11 11 .433 .433 8.5 .335 .217 5.5 .226 5.75 .187 .187 .098 .098 2.5 2.5 7.65 .301 4.1 .161 0.5 .020 0.5 .020 .020 0.5 0.5 .020 2 .079 2 .079 .187 4.75 4.754.75 .197 .315 .197 585 compatible with tab terminal #187 series receptacle. plug-in type (3 form c) external dimensions schematic (bottom view) 10 11 9 8 3 6 7 1 2 4 5 cad data dimension: less than 2mm .079inch: min. 2mm .079inch less than 9mm .354inch: min. 9mm .354inch less than 20mm .787inch: min. 20mm .787inch: t oler ance 0.2 .008 0.5 .020 1 .039 1.5 .059 0.5 .020 44 7 .276 51 1.732 2.008 36 1.417 10 10 .394 .394 25 .984 5.26 7 9 5 4 3 12 14 8 5.26 5.26 5.26 .207 .207 .207 .207 50 1.969 40 1.575 10 .394 .031 .031 .031 .031 0.8 0.8 0.80.8 9 15 11 2 5.26 9.5 .374 7.5 .295 5.8 .228 5.3 .209 5.26 .207 .207 0.8 0.8 .031 .031 1 10 compatible with tab terminal #205 series receptacle. plug-in type (4 form c) external dimensions schematic (bottom view) 9 15 10 8 7 12 5 11 2 1 14 6 3 4 cad data dimension: less than 2mm .079inch: min. 2mm .079inch less than 9mm .354inch: min. 9mm .354inch less than 20mm .787inch: min. 20mm .787inch: t oler ance 0.2 .008 0.5 .020 1 .039 1.5 .059 asctb81e 201201-t panasonic corporation automation controls business unit industrial.panasonic.com/ac/e
hp safety standards for cautions for use. ul/c-ul (recognized) csa (certi?d) file no. contact rating file no. contact rating e43028 10a 250v ac, 1 / 3 hp 125, 250v ac, 10a 30v dc lr26550 etc. 10a 250v ac, 1 / 3 hp 125, 250v ac, 10a 30v dc .110 2.8 46.8 1.843 24.7 .972 7 .276 5.5 .217 35.7 1.406 15 .591 .031 .031 0.8 0.8 58 2.283 45.5 1.791 9.5 .374 7.5 .295 5.3 .209 0.8 2.25r .089r 5.26 .207 5.26 .207 4.5 .177 10 .394 5.26 5.26 .207 .207 0.8 .031 .031 5.8 .228 compatible with tab terminal #205 series receptacle. tm type (2 form c) external dimensions schematic (bottom view) 8 7 6 5 1 2 3 4 mounting hole diagram tolerance: 0.1 .004 (pitch for side-by-side mounting) relay space (area shown by the broken line) 2-m.157 screw hole or 2-.177 dia. hole 2-m4 screw hole or 2-4.5 dia. hole 45.5 1.791 2 .079 30 1.181 installed relay nut panel (chassis) spring washer 2-m.157 2-m4 screw 35.7 1.406 52.3 2.059 dimension: less than 2mm .079inch: min. 2mm .079inch less than 9mm .354inch: min. 9mm .354inch less than 20mm .787inch: min. 20mm .787inch: t oler ance 0.2 .008 0.5 .020 1 .039 1.5 .059 cad data .276 7 .118 3 5 .197 20.5 .807 .433 11 38 1.496 16 .630 4.2 .165 73.5 2.894 60 2.362 44 1.732 2.1r .083r 16 .630 .165 4.2 .083r 2.1r 36 1.417 36 1.417 38 1.496 11 11 .433 .433 8.5 .335 .217 5.5 .226 5.75 .187 .187 .187 4.75 4.75 4.75 2.5 .098 2.5 .098 7.65 .301 4.1 .161 0.5 .020 0.5 .020 0.5 .020 0.5 .020 2 .079 2 .079 compatible with tab terminal #187 series receptacle. direct mounting type (3 form c) external dimensions schematic (bottom view) 10 11 9 8 3 6 7 1 2 4 5 mounting hole diagram tolerance: 0.1 .004 (pitch for side-by-side mounting) 40 1.575 60 2.362 2 .079 2-m.157 screw hole (or 2-.165 dia. hole) 2-m4 screw hole (or 2-4.2 dia. hole) relay space (area shown by the broken line) installed relay 38 1.496 16 .630 .197 5 7 .276 .807 20.5 .433 11 73.5 2.894 2.362 60 44 1.732 2-m.157 2-m4 screw spring washer panel (chassis) nut 36 1.417 dimension: less than 2mm .079inch: min. 2mm .079inch less than 9mm .354inch: min. 9mm .354inch less than 20mm .787inch: min. 20mm .787inch: t oler ance 0.2 .008 0.5 .020 1 .039 1.5 .059 cad data asctb81e 201201-t panasonic corporation automation controls business unit industrial.panasonic.com/ac/e


▲Up To Search▲   

 
Price & Availability of HP3-AC100V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X